Rental: 7 station bop closing unit. jeff@jeffweber.net
Information
Rental: 7 station bop closing unit. jeff@jeffweber.net

Listing ID: 1563
Title: Rental: 7 station bop closing unit. jeff@jeffweber.net
Model: 7 STATION BOP CLOSING UNIT, MANUFACTURED AND WARRANTEED BY CONSOLiDATED PRESSURE CONTROL
Price: on request
Quantity: 1 of each
Condition: ready to work
Location: UK
Date Posted: 2019-06-28 14:28:14
Contacts:

Email: jeff@jeffweber.net

Skype: jeffreyweber

EU office:

Mobile: +370-616-57086
Phone: +370-5-261-0884

US office:

Phone: +1-302-231-1880
Description

ITEM 10: (1) 7 STATION BOP CLOSING UNIT, MANUFACTURED AND WARRANTEED BY CONSOLIDATED PRESSURE CONTROL, LLLP. AS DESCRIBED BELOW


1.0 Fluid requirements 7 station BOP Closing unit Please provide stack configuration with Make/Model/Size/PSI
** Useable fluid of bottles is determined by fluid required to close/open/close all BOP stack functions and close all valves. Final stack configuration must be provided by customer prior to work order to ensure proper sizing**


2.0 Accumulator Module R7S11.20

2.1 Used carbon steel fluid reservoir tank. Tank complete with baffles and inspection port. Tank is designed to accommodate 6 selector valves , rebuilt with Barksdale repair kits, all plumed to a common manifold supplied by Rebuilt 4 way Bypass Valve with Rebuilt 2100 Series hydraulic pressure regulator to shift between regulated or full system working pressure, Rebuilt, 4 way Annular valve with 2100 Series/and New Air Driven, Fail Safe and New Gauge Panel to monitor Accumulator, Manifold and Annular pressures.

2.2 (4) – 6 port machined steel tube bottle manifolds rated for 5000psi working pressure. Manifold is machined from a single piece and MPI tested with certificates available. Isolation of manifold is controlled with a 1” 5000psi ball valve. Manifold is bled back into the reservoir through a 5000psi ½” needle valve.

2.3 (24) – Rebuilt, 11 gallon 3000psi bottom loading bladder type accumulators are inspected and hydro-tested to 4500psi. UA-1 Certificates provided.

2.4 (1) – ¾” Pressure relief valve set by CPC to 3500psi and vented into reservoir has COC included.



2.5 Module is mounted on a steel skid designed to also accommodate mounting of primary and secondary pump systems.



3.0 Primary pump system

3.1 (1) – Rebuilt, Union type triplex reciprocating plunger pump.

3.2 (1) – New 25 HP Explosion proof motor, service factor 1.15 to allow for maximum ambient continuous running conditions of 40

3.3 System is tied into an independent Hydro-electric pressure switch set to maintain system pressure between 2750 and 3150 psi.

3.4 System is fitted on suction side with strainers, isolation valves and suction valves, and on the discharge side with a check valve rated 5000 psi.


4.0 Secondary pump system

4.1 3-NEW Speedflow air pumps. These pumps deliver a 40:1 pressure ratio. The large fluid end delivers 4 gpm per pump, at optimal working pressure. Operating independently this system will allow pressuring of the unit and closing of the Annular at API 16D time requirements. Total air consumption per pump is 40 SCFM per gallon of output @ 100 psi in.

4.2 System is controlled with hydro pneumatic pressure switch. This maintains unit pressure between 2750 and 3150 psi.

4.3 System suction side is regulated by a bypass gate valve and gate valves to isolate each air pump. System is plumbed on suction side with water trap and lubricator for the air, and suction valves and strainers for the fluid. Fluid discharge for each pump is plumbed with 5000 psi check valves.


5.0 Pneumatic Drillers remote panel for control of BOP closing unit

5.1 Assembly is manufactured from carbon steel. All tubing is stainless steel with brass fittings.

Room on unit to upgrade to 2 air remotes.